80
vacon parameters
8
8.6 Digital inputs (Control panel: Menu PAR -> P5)
Code Parameter Min Max Unit Default ID Note
P5.1
I / O control signal 1 0 Varies 1 403
0 = Not used
1 = DI1
2 = DI2
3 = DI3
4 = DI4
5 = DI5
6 = DI6
7 = DIE1
8 = DIE2
9 = DIE3
10 = DIE4
11 = DIE5
12 = DIE6
P5.2 I / O control signal 2 0 Varies 2 404 As parameter 5.1
P5.3 Reverse 0 Varies 0 412 As parameter 5.1
P5.4 Ext. fault Close 0 Varies 6 405 As parameter 5.1
P5.5 Ext. fault Open 0 Varies 0 406 As parameter 5.1
P5.6 Fault reset 0 Varies 3 414 As parameter 5.1
P5.7 Run enable 0 Varies 0 407 As parameter 5.1
P5.8 Preset speed B0 0 Varies 4 419 As parameter 5.1
P5.9 Preset speed B1 0 Varies 5 420 As parameter 5.1
P5.10 Preset speed B2 0 Varies 0 421 As parameter 5.1
P5.11 Ramp time 2 selection 0 Varies 0 408 As parameter 5.1
P5.12 Motor potentiometer up 0 Varies 0 418 As parameter 5.1
P5.13
Motor potentiometer
down
0 Varies 0 417 As parameter 5.1
P5.14 Remote control place 2 0 Varies 0 425
Activates control place 2
As parameter 5.1
P5.15
Remote control plece
freq reference 2
0 Varies 0 343
Activates control place 2
See parameter 5.1
P5.16 PID setpoint 2 0 Varies 0 1047
Activates reference 2
As parameter 5.1
P5.17 Motor PreHeat Active 0 Varies 0 1044
Activates the Motor Pre-
Heat (DC-Current) in
stop state when parame-
ter Motor Preheat func-
tion is set to 2
As parameter 5.1
Table 8.6: Digital inputs