EasyManua.ls Logo

Valor H6 - Appliance Height in Framing; Appliance Depth in Framing

Default Icon
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
Appliance Height in Framing
Hearth considerations
Only a non-combustible hearth can be installed in
front of the appliance if within 4” of the bottom of the
appliance.
The top surface of the non-combustible hearth must
be at the same level as appliance bottom panel when
using certain trims and accessories—see pages
14-16.
The non-combustible hearth in front of the appliance,
if within 4” of the bottom of the appliance, must in-
clude the 1/2Micore insulation board provided to be
used as thermal break between non-combustible and
combustible material underneath.
Appliance Depth in Framing
1430 Fixed Framing Kit and 1430CIK Clean Install Kit
install at framing stage and the appliance position is
xed in the framing. In both cases, the wall nishes
butt up to the frame of the kit.
All other trims install after the wall nish is applied.
The perimeter of the trims overlap the wall nish;
therefore the thickness of any wall nish materials
must be taken into consideration. The trims have
enough adjustability to allow up to 3/4” thick material
applied over top of the 1/2” thick non-combustible
board. Otherwise the appliance position within the
framing must be adjusted to allow the additional
thickness—see page 25.
Planning Framing