When ‘safety mode’ is entered from operation (i.e. pressure control mode), the unit will automatically 
switch to position control mode and remain at current position. Once motor interlock is deactivated the 
unit remains in position control mode. 
 
 
 
5.7  Operation during power up 
Valve position 
before  
Valve power up configuration = closed 
(default) 
Valve power up configuration = open 
Closed (isolated)  Valve remains closed.  
Display shows ‘C  C’. 
Homing will be done when first 
movement command is received. 
Valve runs to maximum throttle position 
to detect the limit stops to do homing. 
Display shows configuration of product 
resp. ‘Ho’ until homing is done.  
Valve position after power up is  
‘A.  0’ min. conductance. 
All other than closed 
(not isolated) 
Valve runs to max. throttle position to detect limit stop for homing. Display shows 
configuration of product resp. ‘Ho’ until homing is done, and afterwards to close 
position. Display shows ‘C  C’. 
Valve position after power up is closed  Valve position after power up is open 
 
Refer also to chapter: «Display information». 
 
 
5.8  Behavior in case of power failure 
Valve position 
before  
power failure: 
Without Power Failure Option (PFO) 
653 . . - . . G  . - . . . . 
653 . . - . . A  . - . . . . 
653 . . - . . T  . - . . . . 
653 . . - . . 
  . - . . . . 
With Power Failure Option (PFO) 
653 . . - . . H  . - . . . . 
653 . . - . . C  . - . . . . 
653 . . - . . U  . - . . . . 
653 . . - . . 
  . - . . . . 
Closed (isolated)  Valve remains closed. 
 
Valve will close or open depending 
on valve configuration 1). 
Default is not defined. 
Display indicates F. 
Valve open or in any 
intermediate position 
Sealing ring moves down and blocks 
the pendulum plate at the current 
position. 
 
1) Provide that battery pack of the VAT controller is charged. Charging time after power up is 2 minutes 
max.. 
 
 
All parameters are stored in a power fail save memory.