Series 65  INSTALLATION 
 
963283EA  Edition 2019-05-03  23/
 
4.2.4  Tightening torque 
 
Tighten mounting screws of the flanges uniformly in crosswise order. Observe the maximum torque levels 
in the following tables. 
 
4.2.5  Mounting with centering rings 
 
Valve size 
ISO-F  ISO-F 
max. tightening torque 
(Nm) 
max. tightening torque 
(lbs . ft) 
DN100 / 4“ 
(65340 - . . . . - . . . . ) 
8-10  6-8 
DN160 / 6“ 
(65344 - . . . . - . . . . ) 
13-15  9-11 
DN200 / 8“ 
(65346 - . . . . - . . . . ) 
13-15  9-11 
DN250 / 10“ 
(65348 - . . . . - . . . . )
17-20  13-15 
 
hole depth (mm)  hole depth (inch) 
DN100 / 4“ 
(65340 - . . . . - . . . . ) 
12  0.47 
DN160 / 6“ 
(65344 - . . . . - . . . . ) 
14  0.55 
DN200 / 8“ 
(65346 - . . . . - . . . . ) 
15  0.59 
DN250 / 10“ 
(653
 - . . . . - . . . . )
16  0.63 
 
 
 
 
The torque values below are dependent on many factors, such as materials involved, 
surface quality, surface treatment, and lubrication. 
 
The torques  below  are  valid if immersion depth of the  mounting  screws  is  at least 
once  the thread  diameter  (min.  1d), and  the  friction coefficient  of  the  screw-flange 
connection  (µ
total 
=  (µ
screw  thread-helicoil
  +  µ
under  screw  head
)/2)  is  bigger  than  0.12.  Lower 
friction  coefficients  may  damage  the  valve, as  the  resulting  preload  force  gets  too 
high. Therefore for other friction coefficients the torque needs to be adapted. Please 
review design guidelines for Helicoil-Screw connections and make sure that screws in 
use are capable to withstand applied torques, are appropriate for the application and 
are not too long. Too long screws may damage the valve, the immersion depth should 
 
 
Refer to «Spare parts / Accessories» for centering rings ordering numbers.