INSTALLATION  Series 
 
70/129
Edition 2019-05-03  963283EA
 
Inquiry function 
Command  Acknowledgement 
Description 
DEVICE STATUS 
Get 
i:30  i:30abcdefgh 
data length  8 characters 
a  Access Mode 
0
=
local operation 
   
1
=
remote operation 
   
2
=
locked remote operation 
b  Control Mode 
1
=
synchronization 
   
2
=
POSITION CONTROL 
   
3
=
CLOSED 
   
4
=
OPEN 
   
5
=
PRESSURE CONTROL 
   
6
=
HOLD 
   
7
=
LEARN 
   
8
=
INTERLOCK OPEN (by digital input) 
   
9
=
INTERLOCK CLOSED (by digital input) 
   
C
=
power failure 
   
D
=
safety mode 
   
E
=
error (read «ERROR STATUS» for details) 
c  Power Failure Option
0
=
disabled 
   
1
=
enabled 
d  Warning 
0
=
no warnings 
   
1
=
 
(read «WARNINGS» and «ERROR STATUS» for details) 
efg  Reserved     
h  Simulation 
0
=
normal operation 
   
1
=
system simulation running 
This function returns status information about the valve. 
Remark: In simulation mode the valve can demonstrate pressure control capability 
independent of other equipment such as vacuum chamber, flow controller and gauge. 
Normal operation is not possible when simulation is running.