Series 65 INSTALLATION
963283EA Edition 2019-05-03 75/
129
data length 8 characters
a
Valve position after power up
0
=
close
1
=
open
b
Valve position after power failure
0
=
close
1
=
open
c
External isolation valve function
0
=
no
1
=
yes
d Control stroke limitation
0
=
no
1
=
yes
e Network failure end position
0
=
valve will close
1
=
valve will open
2
=
valve stay on actual position
f
Slave offline position
0
=
valve will close
1
=
valve will open
2
=
valve stay on actual position
g Synchronization start
0
=
standard
1
=
special command
2
=
open command
3
=
all move commands
4
=
always
h Synchronization mode
0
=
short
1
=
full
This function does the valve configuration.
Setup function
Command Acknowledgement
Description
SENSOR
CONFIGURATION
Set
s:01abcdefgh s:01
Get
i:01 i:01abcdefgh