EasyManua.ls Logo

VAT 653 Series - Page 80

VAT 653 Series
129 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION Series
65
80/129
Edition 2019-05-03 963283EA
Setup function
Command Acknowledgement
)
Description
INTERFACE
CONFIGURATION
Set
s:20abcdefgh s:20
Get
i:20 i:20abcdefgh
data length 8 characters
a baud rate:
0 = 600
1 = 1200k
2 = 2400
3 = 4800
4 = 9600
5 = 19.2k
6 = 38.4k
7 = 57.6k
8 = 115.2k
b parity bit:
0 = even
1 = odd
2 = mark
3 = space
4 = no
c data length:
0 = 7 bit
1 = 8 bit
d number of stop bits:
0 = 1
1 = 2
e 0 = IC
8 = PM-V2
f digital input OPEN VALVE:
0 = not inverted
1 = inverted
2 = disabled
g digital input CLOSE VALVE:
0 = not inverted
1 = inverted
2 = disabled
h 0 (reserved, do not change)
This function does the 0interface0 and digital input configuration.
Remark: Digital outputs are always enabled.
INTERFACE
CONFIGURATION 2
Set
s:22abbbcxxx s:22
Get
i:22 i:22abbbcxxx
data length 8 characters
a 1 = RS485, 2 = RS485 / Point to Point
bbb RS485 address 0...255
c 0 = full duplex, 1 = half duplex
xxx 000 (reserved, do not change)
This function defines the interface configuration for the valve.