9 Set up with the display and adjustment module
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66190-EN-221107
volumeisdesired.Thesameappliestoowmeasuringconstructions
andtherelationshipbetweenowandlevel.
Corresponding linearisation curves are stored for these measurement
situations. They indicate the relationship between the percentage
levelandthevesselvolumeorowrate.Theselectiondependson
the selected linerarisation type liquid or bulk solid.
Note:
The selected linearisation applies to the measured value indication
and the signal output.
Depending on the medium and the vessel bottom, the intermediate
height is also entered, see next menu item.
The intermediate height is the beginning of the cylindrical area, e.g.
for vessels with conical bottoms.
In the menu item " Scaling"youdenethescalingvariableandunitas
well as the scaling format. By doing so, it is for example the indica-
tion of the level measured value for 0 % and 100 % on the display as
volume in l is possible.
This menu item enables the setting of the requested national lan-
guage.
The following languages are available:
•
German
•
English
•
French
•
Spanish
•
Portuguese
•
Italian
•
Dutch
•
Russian
•
Chinese
•
Japanese
Linearization - Intermedi-
ate height
Scaling
Display - Menu language