Viessmann VITOCELL 100-U - Connection on the Heating Side with Return Temperature Limit

Viessmann VITOCELL 100-U
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vitocell 100-V and 300-V as a cylinder bank
Connections on the heating water side
A
DHW
B
Temperature sensor/temperature controller
C
Heating water return
D
Cold water
E
Heating water flow
F
Air vent valve
G
Drain
Connection on the heating side with return temperature limit
The return temperature limiting facility only needs to be installed if
required by the relevant district heating plant.
To ensure that the heating water return temperature cannot exceed a
specified value, use a return temperature limiter with control valve
(e.g. as offered by Samson, type 43-1, control range 25 to 70 ºC).
For individual cylinders and cylinder banks, install the sensor as shown
in the relevant diagrams. The customer is responsible for installing the
necessary pipework.
The control valve is sized according to the required heating water flow
rate and the system pressure drop.
Note
When return temperatures are restricted, a check must be carried out
to determine whether the hygiene requirements in accordance with
TRWI/DVGW are met. A transfer pump may have to be provided.
Vitocell 100-V and Vitocell 300-V (type EVI)
Installation of the sensor for limiting the return temperature in the heating water return for individual cylinders.
R1¼
A
Water temperature controller
B
Gland fitting
C
Tee
D
Fitting
E
Thermal insulation
F
Sensor for the return temperature limiter
G
Indirect coil
H
Heating water return
K
Sensor for return temperature limiter
L
Sensor for water temperature controller
M
Heating water flow
Vitocell 100-V and 300-V as a cylinder bank
Installation of the sensor for limiting the return temperature in the heating water return.
Installation — DHW cylinders
(cont.)