38 - ENGLISH
6.8.3
Insert the MASTER smart card already
programmed by the reader/programmer.
6.8.4
The LED turns off to indicate that the
MASTER smart card has been recog-
nised.
If the smart card is not recognised, the LED turns
red and remains illuminated until the card is re-
moved.
The device waits for the currently active MASTER
smart card for about 2 minutes, after which the
LED turns yellow and no further commands are
accepted.
To resume normal operation, place dip-switch 1
in the OFF position.
6.8.2
Press the front button within 9 seconds.
The LED turns green.
Warning!
If the button is not pressed within 9 seconds,
the LED turns green and the system switches to
the “Initialise reader and program SLAVE smart
card” procedure. To exit the procedure, place
dip-switch 1 in the OFF position.
Repeat the procedure from step 6.8.1.
6.8.1
Place dip-switch 1 on the reader being
synchronised in the ON position.
The LED lights up yellow.
1 2 3
4 5 6
7 8
ON
yellow
green
MASTER
card
MASTER
card
2 minutes
MASTER
card
MASTER
card
green
yellow
off