3. For presetting the Ethernet data click to [...] and click to [Acces-
sible nodes].
4. Click at [Determining accessible nodes].
ð
After a waiting time every accessible station is listed.
5. Choose your CPU, which was provided with TCP/IP address
parameters during the hardware configuration and click to [Con-
firm].
6. Close the dialog ‘Ethernet properties’ with [OK].
7.
T
ransfer your project to your CPU with ‘PLC è Send all blocks’.
8. Switch your CPU to RUN state.
9. Open the OB 1 by double click.
10. Change the value of one variable, save the OB 1 and transfer it
to the CPU.
ð
According to your settings the process image changes
immediately
. The status of your blocks may be displayed with
‘Block è Monitoring On/Off’.
VIPA System 300S WinPLC7
Example project engineering > Transfer PLC program to CPU and its execution
HB140 | CPU | 314-6CF03 | GB | 16-43 215