Display, Keys and Menus
Setup Menus
VT400 Technical Manual, Rev. A5 32 Doc # UM-VT400-EN
A-CAL (Analog Output, cont.)
Par. Description Values
A.4 Current / voltage. This parameter must correspond to the
hardware jumper, which defines whether output should be in
current or voltage (see section 7.4.1). The default setting is
voltage (1).
0 = Current
1 = Voltage
A.5 Net / gross. Specifies whether the indicator should always
output gross weight, or output net weight when tare is active.
0 = Net weight
1 = Gross weight
A.6 Effective Range for current output. Sets the range to 0-
20mA or 4-20mA. Relevant only if A.4 and the hardware
jumper are set to current.
0 = 0-20mA
1 = 4-20mA
A.7 Resolution. Specifies whether output should be in high
resolution if the display is showing high resolution.
0 = Display
1 = Internal
A.8 Operation. Enables and disables the analog output. 0 = Disabled
1 = Enabled