Troubleshooting
8.2 Checking Hydraulic Pressure
78
Operator’s Manual | RTLx-SC3 | 5100061327 | 09/2022 | [en-US]
Problem /
Symptom Reason Remedy
Compatec
compaction
system LEDs
permanently
flashing
(if equipped)
Sensor failure Repair or replace.
1
1
Contact your authorized dealer/service center.
8.2 Checking Hydraulic Pressure
There are two test ports for checking the hydraulic pressure. (For further in-
formation, see Hydraulic Manifold on page 79.)
Exciter test port (G-EP)
High vibration pressure Low vibration pressure
2,500 ± 100 psi (172 ± 7 bar) 1,200 ± 100 psi (83 ± 7 bar)
Drive test port (G-DP)
Joystick full forward position
2,700 ± 100 psi (207 ± 7 bar)

Table of Contents