Maintenance
Periodic Maintenance Schedule 7.1
65
[en-US] | 09/2022 | 5100061327 | RTLx-SC3 | Operator’s Manual
7 Maintenance
7.1 Periodic Maintenance Schedule
Maintenance cycle Personnel For further information
Daily Operating personnel
[}65]
Checking the Hydraulic Oil Level
[}69]
Checking for Loose or Missing Fasteners
[}69]
Checking the Receiving Eyes
[}70]
Cleaning SmartControl™ Transmitter
100 hours Operating personnel
[}66]
Maintaining the Battery
[}69]
Lubricating the Articulated Joint and Steering
Cylinders
[}71]
Draining the Fuel and Water Separator
300 hours Operating personnel
[}71]
Inspecting the Shock Mounts
1000 hours Service personnel
[}67]
Changing the Hydraulic Oil and Filter
As needed Operating personnel
[}66]
Maintaining the Battery
[}70]
Adjusting the Scraper Bars
[}72]
Priming the Fuel System
Maintenance personnel
[}82]
Machine Disposal and Decommissioning
7.2 Checking the Hydraulic Oil Level
NOTICE
Low levels of hydraulic oil may cause damage to hydraulic components.
If hydraulic oil continually needs to be added, inspect the hoses and
connections for possible leaks. Repair any leaks immediately.
Do not attempt to remove the vent cover from the hydraulic reservoir.
When
Daily
Requirements
Location
A hydraulic oil level sight glass (1) is located on the side of the hydraulic fluid
reservoir inside the rear section of the machine.
7

Table of Contents