6.7.1 GROUNDING THE POWDER COATING SYSTEM
1 Only use mains cables with grounding strand!
2 Connect grounding cable with booth and signal ground!
3 Connect grounding cable to an uncoated metal part of the booth!
4 Remove all paint from hooks and other hanger parts!
5 Do not wear non-conducting gloves!
6 Wear electrostatically conductive footwear!
7 The  oor must be electrostatically conductive!
8 Connect  oor and booth with system ground!
The control unit is grounded with the grounding cable supplied. The grounding cable is
secured to the control unit's grounding connection and the rack with the screws provided.