3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION
The device is suited for use in potentially explosive areas, in accordance with Test Certi cate
PTB 12 ATEX 5001.
0102
II 3(2)D IP 64 80 °C
CE: European Communities
0102: Noti ed body
Ex: Symbol for explosion protection
II: Device class II
3: Category 3 (Zone 22)
(2): Impact on equipment of category 2
D: Ex-atmosphere dust
IP64: Protection class 64
80 °C: Temperature class: maximum surface temperature < 80 °C; 176 °F
3.2 PERMISSIBLE DEVICE COMBINATIONS
The following powder spray guns may be connected to the EPG S2:
Automatic spray guns
– Corona spray gun PEA-C3, PEA-C4
– Corona spray gun PEA-C3XL, PEA-C4XL
– Tribo spray gun PEA-T3
– Tribo spray gun PEA-T3XL
Manual spray guns
– Corona spray gun PEM-C3, PEM-C4 HiCoat, PEM-C4 Ergo,
PEM-X1
Older or other gun types may only be connected to the control unit after rst checking