Operating manual Manual system SPRINT 2
3 Identification
10 Order number 2467031 | Edition 04/2024
3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION
3.1.1 Mobile base identification
Device type Sprint 2 mobile base
Manufacturer Wagner International AG
9450 Altstätten
Switzerland
II3DExhIIIBT100°CDc
CE European Communities
Ex Symbol for explosion protection
II Device class II
3 Category 3
D Ex-atmosphere dust
Ex Ignition protection class
h Ignition protection class for non-electrical devices
IIIB Explosion group (dust group)
T100°C
Temperature class, maximum surface temperature < 100 °C; 212 °F
Dc Device protection level, suitable for use in Zone 22
3.2 PERMISSIBLE DEVICE COMBINATIONS
WARNING
Incorrect use!
Risk of injury and damage to the device.
4 Only use the manual system with the original WAGNER control units and powder
spray guns.
Only use the Sprint 2 manual system with the following guns and control units:
Control units Guns
WACON Sprint 2 PEM-X1 Corona spray gun, PEM-X1 CG
PEM-T3 Tribo spray gun
For permissible device combinations for the USA and Canada, see chapter FM Control document
[8
60].