Operating manual Manual system SPRINT 2
7 Operation
36 Order number 2467031 | Edition 04/2024
7 OPERATION
7.1 TRAINING THE OPERATING PERSONNEL
– The operating personnel must be qualified to operate the entire system.
– The operating staff must be familiar with the potential risks associated with improper behavior
as well as the necessary protective devices and measures.
–
Before work commences, the operating personnel must receive appropriate system training.
7.2 TASKS
1. Ensure that:
4 the regular safety checks are carried out in accordance with chapter
Safety checks
[8 45];
4 commissioning is carried out in accordance with chapters Assembly of the manual
system [8
21] and Connecting the manual system [823].
7.2.1 Switching on the manual system
To turn the power supply of the manual system on, set the main switch 1 on the back side of
the control unit to position [I].
– After a few seconds the control unit is operational.
– The device switches to recipe2 [Surface parts] after every restart.
– To switch the manual system off or on, actuate the [Standby] push button(3).
Note:
– The fluid air must be adjusted using the throttle(4), when first commissioning the
manual system.
– The control unit automatically recognizes the type of gun connected.
– There are 50 recipes available for the gun.
– When a Tribo gun is connected, the Tribo current scale is activated, while the
high-voltage supply and control unit are deactivated.
– All airs are only switched on once the manual gun's trigger has been actuated.