Operating manual Manual system SPRINT 2
7 Operation
Order number 2467031 | Edition 04/2024 39
7.3 FACTORY SETTING RECIPE NOS. 1–4
The following set values are stored in recipe nos. 1–4 in the factory.
Recipe no. Designation Characteristic High voltage
[kV]
Current limitation
[µA]
Character-
istic curve
Total air
[m
3
/h]
Feed air
[%]
Atomizing air
[m
3
/h]
P01 Flat part High surface cov-
erage
90 80 Standard 3.5 60 0.1
P02 Profile part Penetration and
reduced build-up
of edges
60 20 Medium 2.9 40 0.1
P03 Second coat-
ing
Avoidance of
spraying back
50 10 Soft 2.9 45 0.1
P04 Double click Blow-off function 0 0.5 Medium 0.0 0 2.0
P05–50 Variable individual 80 100 Standard 4.5 80 0.1
Info
Under normal conditions, metallic powder can be processed well using recipes Nos.1–4.
When operating the system with a Tribo gun, the values for total air, powder feed and Tribo air must be adjusted accordingly and saved.
With the 3 L tank variant, the values must also be adjusted individually and saved.