Operating manual Manual system SPRINT 2
8 Cleaning and maintenance
Order number 2467031 | Edition 04/2024 47
6. Pull the black fluid air hose(9) off the powder tank(8).
7. Loosen the grounding cable10 from the powder tank8.
8. Lift the powder tank off of the equipment mobile base for cleaning.
9. Remove the lid of the powder tank to empty the powder tank and thoroughly blow out
the powder tank.
10. Completely remove all residual powder from the suction system.
11. Thoroughly clean the fluid base, check it for clogging or damage and replace it if
necessary. The wearing and spare parts are listed in chapter Spare parts [853] of the
operating manual.