PAGE 35
© 2014 OJ Electronics A/S
Temperature Scale 1/3
This option allows you to set the minimum and maximum temperature to which
the thermostat can be set – as well as the minimum and maximum limits for floor
temperature.
Operating temperatures:
• Minimumtemperaturecanbesetbetween5°Cand15°C.
• Maximumtemperaturecanbesetbetween20°Cand40°C.
(If “Sensor Application” is set to “Floor”, a maximum temperature of 27°C can
protect wooden floors from drying out. For precise information, please ask your
flooring supplier).
Floor limit temperatures:
Floor limit temperatures allow you to set the lowest (Minimum Limit Temp.) and
highest (Maximum Limit Temp.) permissible floor temperature during normal room
temperature control. If floor temperature drops below the Minimum Limit Temp.,
the thermostat will activate the heating system to maintain the temperature above
the set minimum. If floor temperature rises above the Maximum Limit Temp., the
thermostat will deactivate the heating system to maintain the temperature below the
set maximum.
Floor Limit temperatures are only available if “Room/Floor Limit” has been selected
under “Sensor Application”.