43
1
2
3
10.2.6. Cleaning / changing the air lter
Shutothemachineasdescribedinsection5.8.
Open the hoods as described in section 10.2.1.
Open the brackets (1) to remove the cap (2).
Removetheairlter(3)andclean/replaceit.
Cleantheairlterwithcompressedair–
max.5bar.Blowthedirtoutoftheairlter
from the inside out.
Should complete cleaning with compressed air no longer be possible on account of
damporoilydirt,theairltermustbereplaced.
Makesuretheairlterisrmlyseatedwhen
reinstalling it. The cleaning opening on the cap (2)
must point down vertically.
Close the brackets (1) carefully.
WARNING
Riskofbreathingdiculties,includingsuocation,
fromthedustproducedwhileblowingouttheairlter.
Onlyblowouttheairlterinwell-ventilatedlocations.
Wear a dust mask.