EasyManua.ls Logo

WEG CFW-11 Series - Electronics;General Data

WEG CFW-11 Series
145 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specications
8
CFW-11 | 8-7
8.2 ELECTRONICS/GENERAL DATA
Control Method Voltage source
Type of control:
- V/f (Scalar)
- VVW: Voltage Vector Control
- Vector control with encoder
- Sensorless vector control (without encoder)
PWM SVM (Space Vector Modulation)
Full digital (software) current, flux, and speed regulators
Execution rate:
- current regulators: 0.2 ms (switching frequency of 2.5 kHz and 5 kHz), 0.25 ms (switching frequency = 2 kHz)
- flux regulator: 0.4 ms (switching frequency of 2.5 kHz and 5 kHz), 0.5 ms (switching frequency = 2 kHz)
- speed regulator / speed measurement: 1.2 ms
Output
Frequency
0 to 3.4 x rated motor frequency (P0403). The rated frequency is programmable from 0 Hz to 300 Hz
in the scalar mode and from 30 Hz to 120 Hz in the vector mode
Output frequency limits as a function of the switching frequency:
125 Hz (switching frequency = 1.25 kHz)
200 Hz (switching frequency = 2.0 kHz)
250 Hz (switching frequency = 2.5 kHz)
500 Hz (switching frequency = 5 kHz)
Performance Speed
Control
V/f (Scalar):
Regulation (with slip compensation): 1 % of the rated speed
Speed variation range: 1:20
VVW:
Regulation: 1 % of the rated speed
Speed variation range: 1:30
Sensorless (P0202 = 3 asynchronous motor):
Regulation: 0.5 % of the rated speed
Speed variation range: 1:100
Vector with Encoder (P0202 = 4 asynchronous motor or P0202 = 6 permanent magnet):
Regulation:
±0.01 % of the rated speed with a 14-bits analog input (IOA)
±0.01 % of the rated speed with a digital reference (Keypad, Serial, Fieldbus, Electronic
Potentiometer, Multispeed)
±0.05 % of the rated speed with a 12-bits analog input (CC11)
Speed variation range: 1:1000
Torque
Control
Range: 10 to 180 %, regulation: ±5 % of the rated torque (P0202 = 4, 6 or 7)
Range: 20 to 180 %, regulation: ±10 % of the rated torque (P0202 = 3, above 3 Hz)
Inputs
(CC11 Board)
Analog 2 isolated differential inputs; resolution of AI1: 12 bits, resolution of AI2: 11bits + signal, (0 to 10) V,
(0 to 20) mA or (4 to 20) mA, Impedance: 400 kΩ for (0 to 10) V, 500 Ω for (0 to 20) mA or
(4 to 20) mA, programmable functions
DIGITAL
6 isolated digital inputs, 24 Vdc, programmable functions
Outputs
(CC11 Board)
Analog 2 isolated analog outputs, (0 to 10) V, R
L
10 kΩ (maximum load), 0 to 20 mA / 4 to 20 mA (R
L
500 Ω)
resolution: 11 bits, programmable functions
Relay
3 relay outputs with NO/NC contacts, 240 Vac, 1 A, programmable functions
Safety Protection Output overcurrent/short-circuit
Under/Overvoltage
Phase loss
Overtemperature
Braking resistor overload
IGBTs overload
Motor overload
External fault/alarm
CPU or memory fault
Output phase-ground short-circuit
Integral
Keypad
(HMI)
Standard
Keypad
9 operator keys: Start/Stop, Up arrow, Down arrow, Direction of rotation, Jog, Local/Remote, Right
soft key and Left soft key
Graphical LCD display
View/edition of parameters
Indication accuracy:
- current: 5 % of the rated current
- dc link voltage: 3 % for frame sizes B, C, D and E; 5 % for frame sizes F, G and H
- speed resolution: 1 rpm
Possibility of remote mounting