Technical Specications
8
8-8 | CFW-11
Degree of
Protection
IP21 Frame sizes B and C (standard models)
IP20/NEMA1 Frame size D (standard models)
IP20 Frame sizes E, F, G and H (standard models)
NEMA1 Frame sizes B, C and E (with option N1)
IP21 Frame sizes D, E, F, G and H (with option 21)
IP00 Frame sizes F, G and H (with special hardware DC)
IP54 Back of the inverter (external part for flange mounting)
(1)
Pc Connection
For Inverter
Programming
USB Connector USB standard Rev. 2.0 (basic speed)
Type B (device) USB plug
Interconnection cable: standard host/device shielded USB cable
(1) Special hardware H1 – only for frames E (models 125 A and 150 A), F, G and H.
8.3 CODES AND STANDARDS
Safety Standards UL 508C - power conversion equipment
Note: suitable for Installation in a compartment handling conditioned air.
UL 840 - insulation coordination including clearances and creepage distances for electrical
equipment
EN 61800-5-1 - safety requirements electrical, thermal and energy
EN 50178 - electronic equipment for use in power installations
EN 60204-1 - safety of machinery. Electrical equipment of machines. Part 1: general requirements
Note: the final assembler of the machine is responsible for installing an safety stop device and a
supply disconnecting device
EN 60146 (IEC 146) - semiconductor converters
EN 61800-2 - adjustable speed electrical power drive systems - part 2: general requirements - rating
specifications for low voltage adjustable frequency AC power drive systems.
Electromagnetic Compatibility (EMC)
EN 61800-3 - adjustable speed electrical power drive systems - part 3: EMC product standard including
specific test methods
EN 61000-4-2 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques -
section 2: electrostatic discharge immunity test
EN 61000-4-3 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques -
section 3: radiated, radio-frequency, electromagnetic field immunity test
EN 61000-4-4 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques -
section 4: electrical fast transient/burst immunity test
EN 61000-4-5 - electromagnetic compatibility (EMC) - part 4: testing and measurement techniques -
section 5: surge immunity test
EN 61000-4-6 - electromagnetic compatibility (EMC)- part 4: testing and measurement
techniques - section 6: immunity to conducted disturbances, induced by radio-frequency fields
Mechanical Standards EN 60529 - degrees of protection provided by enclosures (IP code)
UL 50 - enclosures for electrical equipment
IEC60721-3-3 - classification of environmental conditions - part 3: classification of groups of
environmental parameters and their severities - section 3: stationary use at weather protected locations
Frame sizes B, C and D: Level 3M4
Frame size E: Level 3M4
IEC 61800-5-1 - adjustable speed electrical power drive systems - part 5-1: safety requirements - electrical,
thermal and energy
Frame sizes F…H: Level 10 Hz to 57 Hz – 0,075 mm of range 57 Hz to 150 Hz – 1g
8.4 CERTIFICATIONS
Certications (*) Notes
UL and cUL E184430
CE
IRAM
C-Tick
EAC
ABS
Link: http://ww2.eagle.org/en/rules-and-resources/type-approval-database.html
After accessing the link, click on “Select Option” and select “Data Search”.
On the new window, the certificate number must be entered on the “Certificate Number” field: 15-RJ2890495.
Click on “Search”.
TÜV STO funtion