13
SOFTPLC
Table 13.1: Description of the parameter P903 options
P903 Description
0 It defines that the application that will run on the SoftPLC is the one loaded by the user through the ladder programming tool
1 It defines that the application that will run on the SoftPLC is the PID controller
!
WARNING!
It is recommended to load the factory setting (P204 = 5 or 6) after alternating between user’s
application and PID controller application.
P904 - Action for SoftPLC Application not Running
Range: 0 = Disabled
1 = Cause Alarm (A708)
2 = Cause Fault (F709)
Description:
It defines which action will be taken by the product in case the SoftPLC not running condition is detected, and it
may generate alarm A708 (1), fault F709 (2) or neither of the previous actions, remaining inactive (0).
13.2 USER
See below the SoftPLC user’s parameters.
P910 - SoftPLC Parameter 1
P911 - SoftPLC Parameter 2
P912 - SoftPLC Parameter 3
P913 - SoftPLC Parameter 4
P914 - SoftPLC Parameter 5
P915 - SoftPLC Parameter 6
P916 - SoftPLC Parameter 7
P917 - SoftPLC Parameter 8
P918 - SoftPLC Parameter 9
P919 - SoftPLC Parameter 10
P920 - SoftPLC Parameter 11
P921 - SoftPLC Parameter 12
P922 - SoftPLC Parameter 13
13-2 | Micro Mini Drives