106 / 144
Analog AVO1/2/3
Voltage of analog AVO1/2/3 when the analog rate is 100%.
Range: [Pressure in idle status, 10]V
Default value: 10
5.3.4 Exhaust
Enable Auto Exhaust
Whether to enable automatic exhaust.
Default value: No
Disable Exhaust Delay
Delay time before disabling exhaust port when leaving out of the area.
Range: [1, 1000]ms
Default value: 1
Start Position of Exhausting
Starting position of exhausting area, in machine coordinate.
Range: [Lower limit of Y-axis, Upper limit of Y-axis]mm
Default value: 0
Exhausting Interval1
Length of No.1 exhausting area.
Range: [10, 10000]
Default value: 1000
Exhausting Interval2
Length of No.2 exhausting area.
Range: [10, 10000]
Default value: 1000
Exhausting Interval3
Length of No.3 exhausting area.
Range: [10, 10000]
Default value: 1000