Min Pulse Width
Minimum allowable pulse width when laser power is controlled by duty ratio.
When pulse width is smaller than this value, this value is used.
When pulse width is larger than this value, pulse width in duty ratio is used.
Range: [0, 1000000]μs
Default value: 5
Adjust Power Mode
During analog adjustment, AVC output = Laser power * Cutting power * Speed
power curve, Duty ratio = PWM duty ratio
During duty ratio adjustment, AVC output = Laser power * Cutting power, Duty ratio
= PWM duty ratio * Speed power curve
0: Analog adjustment
1: Duty ratio adjustment
Default value: 1
Power Increasing Speed
Time for power to increase from 0% to 100%, which can be used to solve the
problem of over burning at the start point.
Range: [0, 1000]ms
Default value: 0