Axis Direction
Moving direction of X-axis.
If the moving direction of X-axis is opposite to the direction judged by Right Hand
Rule when the machine tool is moved manually, modify the value of the this
parameter.
1: Positive
-1: Negative
Default value: 1
PG Frequency Dividing Ratio of X
Ratio of sending pulse to feedback pulse in X-axis.
Positive value: positive direction of axis encoder
Negative value: negative direction of axis encoder
0: not enable encoder feedback
Range: [-10000, 10000]
Default value: -1
Max. Speed
Maximum allowable speed of X-axis.
Range: (0, maximum speed supported by hardware]mm/min
Default value: 60000
Enable Soft Limit Protection
Used to prevent the machine tool from colliding with hard limit switch.
Yes: enable
No: not enable
Default value: Yes
Soft Limit Lower Limit
Lower limit of soft limit.
Range: [-999999, soft limit upper limit)mm
Default value: 0