上海维宏电子科技股份有限公司
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD.
86 / 144
Soft Limit Upper Limit
Upper limit of soft limit.
Range: (soft limit lower limit, 999999]mm
Default value: 1500
5.1.2 Y-axis
Enable Single Y Configuration
Whether to enable single Y configuration.
Yes: single Y configuration
No: double Y configuration
Default value: No
Moving Distance Per Revolution of Motor
Moving diatance per revolution of motor on load axis.
Range: (0, 200]mm
Default value: 100
Pulse Equivalent
Displacement or angle caused by per pulse in Y-axis.
Range: [1E-08, 1000]mm/p
Default value: 0.002
Axis Direction
Moving direction of Y-axis.
If the moving direction of Y-axis is opposite to the direction judged by Right Hand
Rule when the machine tool is moved manually, modify the value of the this
parameter.
1: Positive
-1: Negative
Default value: -1