XY-axis Stepping Speed
Step speed in step mode.
Range: [0.06, Maximum value of maximum speeds between XY-axes]mm/min
Default value: 6000
Z-axis Rapid Jogging Speed
Speed in rapid jog mode.
Range:
Default value: 1800
Z-axis Jogging Speed
Default speed in jog mode.
Range: [0.06, Rapid jogging speed]mm/min
Default value: 1200
Z-axis Stepping Speed
Step speed in step mode.
Range: [0.06, Minimum value of maximum speeds among all axes]mm/min
Default value: 1200
W-axis Jogging Speed
Default speed in jog mode.
Range: [0.06, Rapid jogging speed]mm/min
Default value: 120
5.2.2 Manual Acceleration
X-axis Manual Feed Acceleration
Acceleration in jog mode.
Used to control the acceleration in jog mode.
Range: [16, 100000]mm/ s
2
Default value: 2000