EasyManuals Logo

WEISS EF2 Series User Manual

WEISS EF2 Series
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Manual R06-201650 / 172
ROTARY INDEXING TABLE CONTROLLER EF2...B
SAFETY FUNCTIONS | 5.2 Extended safety functions (SIL3)
Forced dynamization:
The forced dynamisation needs to be carried out every 8 hours.
The forced dynamization of the shutdown paths serves the purpose of detecting errors on time that occur in the soft-
ware and hardware of the two monitoring channels of the integrated safety functions of the SINAMICS S120. It is
automatically carried out by selecting / deselecting the STO function.
A message is displayed for this.
Safety monitoring error:
When a safety error occurs, such as "simultaneity monitoring", the drive will come to a standstill by coasting down on
its own.
The correct operation of the safety device must be confirmed afterwards, e.g. by pressing the "emergency stop"
switch again.
The drive can be moved again only after the safety error has been eliminated and the safety device is reset.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEISS EF2 Series and is the answer not in the manual?

WEISS EF2 Series Specifications

General IconGeneral
BrandWEISS
ModelEF2 Series
CategoryController
LanguageEnglish

Related product manuals