Manual R06-2016 65 / 172
ROTARY INDEXING TABLE CONTROLLER
EF2...B
INSTALLATION | 6.2 Power Module PM240-2; frame size FSA / FSB
6.2.5.1 Permissible motors
Motors should be used for converter operation or with greater isolation.
• Motors for 200-V-Power Modules
Asynchronous motor in the range of 25 % … 150 % of the converter output are permissible without restrictions
for 200-V-Power Modules.
• Motors for 400-V-Power Modules
Asynchronous motor in the range of 25 % … 150 % of the converter output are permissible without restrictions
for 400-V-Power Modules.
6.2.5.2 Motor connection PM240-2, frame size FSA
The plug connections are located on the bottom side of the power module.
Fig. 37: Motor connection PM240-2, frame size FSA
Name
Motor connection plug
Release lever
U2 Motor phase U
V2 Motor phase V
W2 Motor phase W
Protective ground
Screw terminals
Cross-section
Tightening torque
Stripping length
1.5 to 2.5 mm
2
0.5 mm
8.0 mm
Motor terminal block with star bridge Motor terminal block with delta bridge
For terminal identifications refer to terminal block lid
U1
V1
W1
U1
V1
W1