Manual R06-2016 95 / 172
ROTARY INDEXING TABLE CONTROLLER
EF2...B
OPERATION / DESCRIPTION OF WEISS SOFTWARE | 8.3 Machine configuration
I/O configuration PROFINET
1. Select PROFINET interface.
2. Select standard for interface compatibility and byte order in the telegram.
The following description of the I/O configuration is valid for the interface compatibility standard. For EF1 com-
patibility mode see chapter 8.3.5.2 „EF1 compatible configuration“ on page 98.
3. Click the Next button.
➱ The window for entering the PROFINET settings is opened.
The station name has to match the name that was previously declared in the higher-level control-
ler!
Rules for assigning names:
• Only lowercase letters
• Letters a-z and numbers 0-9 are permitted
• Special characters are not allowed: !"§$%&/()=?`*'_:;#+<>|~[]{}
• Spaces are not allowed either
• The name can have a maximum total length of 240 characters
• Reserved names which cannot be used:
"port-xyz" or "port-xyz-abcde…"
• The engineering system replaces invalid characters with an "x".