EasyManua.ls Logo

WinGD X92-B - Page 342

WinGD X92-B
460 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 If there is no oil flow from none of the leakage pipes, find (if applicable) the connecting pipe
that has a leakage as follows:
8.1 Carefully loosen the screw plug of the inspection point of the first connecting pipe
a maximum of two turns.
8.2 Do a check for oil flow.
8.3 If there is an oil flow, shut-off the related connecting pipe an repair it at the next
occasion, refer to the Maintenance Manual.
8.4 Tighten the screw plug.
8.5 Do Step 8.1 to Step 8.4 again for the other connecting pipe.
CLOSE UP
None
X92-B
AA00-0000-00AAA-311A-A
Operation Manual Examine the supply unit for servo oil leakage
Winterthur Gas & Diesel Ltd.
- 342 - Issue 002 2021-11

Table of Contents

Related product manuals