Tab 11-6 Cooling water systems (XX10NN to XX19NN)
Description Usual oper-
ation (value
or range)
Safeguard setting
Medium / physical value / location Signal number Func-
tion
Le-
vel
Trigger
value
De-
lay
Cylinder liner, cylinder cover
HT cylinder cooling water / pressure [bar] /
engine inlet connection 02
2.2 to 4 PT1101A ALM L ≤ 2.0 0
SLD L ≤ 1.8 60
- PS1101S SHD L ≤ 1.5 60
HT cylinder cooling water / temperature [°C] /
engine inlet connection 02
62 to 80 TE1111A ALM L ≤ 60 0
HT cylinder cooling water / temperature [°C] /
outlet each cylinder (engine outlet connec-
tion 03)
90 +/-2
1
90 +/-4
2
TE1121-nnA ALM H ≥ 95 0
SLD H ≥ 97 60
Scavenge air cooler (SAC)
SAC LT cooling water / pressure [bar] / en-
gine inlet connection 07
2.5 to 4 PT1361A ALM L ≤ 2.0 0
SAC LT cooling water / temperature [°C] /
engine inlet connection 07
25 to 36
3
TE1371A ALM L ≤ 21 0
SAC LT cooling water / temperature [°C] /
outlet each SAC
25 to 75 TE1381-nnA ALM H ≥ 80 0
1
This value is applicable for stable operation condition.
2
This value is applicable for transient operation condition.
3
WinGD recommends a setpoint value of 25°C. 36°C is only permitted if the seawater temperature is
32°C.