Data transfer to PC (option)
15 Data transfer to PC (option)
The hygiene logbook can only hold a limited number of entries. Therefore, it is also possible to transfer the
entries to a PC and archive them there.
Refer to the corresponding documents for further information.
16 Disposal
Contact your dealer so that the materials contained in the machine can be recycled as far as possible.
17 Technical data
17.1 Technical data
Factory settings for temperature
Temperatures acc. to DIN 10510
Detergent without
disinfectant component
Cleaner with a sufficient
proportion of a disinfectant
component
Boiler 1: 70 °C
Boiler 2: 82 °C
Factory settings for hygiene logbook
Stored in hygiene logbook
Rinse aid container empty
Detergent container empty
Temperature zone 1 – 6 below requirement
Boiler 1 temperature violation (too high or too
low)
Boiler 2 temperature violation (too high or too
low)
Other events are possible on request