Data transfer to PC (option)
33
15 Data transfer to PC (option)
The hygiene logbook can only hold a limited number of entries. Therefore, it is also possible to transfer the
entries to a PC and archive them there.
Refer to the corresponding documents for further information.
16 Disposal
Contact your dealer so that the materials contained in the machine can be recycled as far as possible.
17 Technical data
17.1 Technical data
Factory settings for temperature
Temperatures acc. to DIN 10510
Area
Detergent without
disinfectant component
Cleaner with a sufficient
proportion of a disinfectant
component
Factory setting
Pre-wash zone
40 to 50 °C
40 to 50 °C
45 °C
Main wash zone
60 to 65 °C
55 to 65 °C
62 °C
Pump rinsing
60 to 70 °C
60 to 70 °C
67 °C
Fresh water rinsing
80 to 85 °C
80 to 85 °C
Boiler 1: 70 °C
Boiler 2: 82 °C
Factory settings for hygiene logbook
Event
Screen display
Stored in hygiene logbook
Rinse aid container empty
Yes
Yes
Detergent container empty
Yes
Yes
Detergent under dosage
Yes
Yes
Service interval expired
Yes
Yes
Temperature zone 1 6 below requirement
Yes, in Info menu
Yes
Boiler 1 temperature violation (too high or too
low)
Yes, in Info menu
Yes
Boiler 2 temperature violation (too high or too
low)
Yes, in Info menu
Yes
Other events are possible on request