7 181 465 347 (01.07)
Rectifying faults
21
Ad flashing.
Heat store NTC sensor 1 not detected
Check Action
1. Is lead for heat store NTC sensor
correctly routed, i.e. not through
cable clamp?
yes: ↓2.
no: B Route connecting lead for heat store tempera-
ture sensor as specified in installation instruc-
tions.
2. B Activate menu option
Show service parameters.
B Select
.3 Stor.tank temp.sensor1 .
Is a temperature between 0. and 5.
displayed?
yes: Connector on end of NTC sensor lead:
B Flue gas connector corroded
1)
, damaged or
dirty? Change relative parts.
B Press button .
Ad? ↓3.
1)
no: ↓4.
3. Heat store -NTC 1:
B Unplug connector from PCB con-
trol board.
B Short circuit the connector using
wire jumper.
After max. 60 sec:
Display changes to temperature
between 100. and 95.
yes: B Replace heat store NTC sensor 1.
no: B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Change PCB control board.
B Reconnect the boiler electrical connection.
B Turn ON the appliance.
4. Temperature between 95. and 100. is
displayed.
B Unplug the connector.
After max. 60 sec.:
Does the displayed code change
to a value between 0. and 5.?
yes: B Replace heat store NTC sensor 1.
no: B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Change PCB control board.
B Reconnect the boiler electrical connection.
B Turn ON the appliance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GREENSTAR HE combi Series and is the answer not in the manual?

Worcester GREENSTAR HE combi Series Specifications

General IconGeneral
BrandWorcester
ModelGREENSTAR HE combi Series
CategoryBoiler
LanguageEnglish

Related product manuals