Rectifying faults
b1 flashing.
Code plug not detected.
Check Action
1. No fault or fault code FC displayed
on text display?
yes: B Power OFF the appliance.
B Fit code plug (correctly), making sure code
number (see Appendix) is correct.
B Turn ON the appliance.
b1? 2.
no: 2.
2. B Activate menu option Show serv-
ice parameters.
B Select 1.2 Code plug.
B Compare number displayed with
that shown in Appendix.
No number or incorrect number
(last three digits) displayed.
yes: 2.
no: 4.
3. Code plug loose, incorrect or defec-
tive.
B Power OFF the appliance.
B Replace code plug
1)
, making sure code number
is correct.
B Turn ON the appliance.
b1? 4.
1) For order no., refer to Appendix
4. The PCB control board is damaged. B Power OFF the appliance.
B Disconnect the boiler electrical connection.
B Change PCB control board.
B Reconnect the boiler electrical connection.
B Turn ON the appliance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GREENSTAR HE combi Series and is the answer not in the manual?

Worcester GREENSTAR HE combi Series Specifications

General IconGeneral
BrandWorcester
ModelGREENSTAR HE combi Series
CategoryBoiler
LanguageEnglish

Related product manuals