Rectifying faults
37
Flue gas levels incorrect, CO level too high
Check Action
1. Does the gas supply type match the
specifications on the appliance iden-
tification plate?
yes: 2.
no: B Convert appliance to correct gas type
1)
.
2. B Test gas supply pressure
1)
, - OK? yes: 3.
no: B Decommission appliance.
B Notify gas company.
3. Problem with flue?
B Check CO
2
level in combustion
air.
> 0,2 % CO
2
?
yes: B Check flue and repair or replace if necessary.
no: 4.
4. Flue gas CO
2
levels measured at
min. and max. load do not match
specified levels?
1)
.
B Measure CO
2
levels.
yes: B Adjust CO
2
levels.
no: 5.
5. Gas volumetric flow too high when
CO
2
level correctly set
1)
.
yes: B Reduce gas volumetric flow rate by means of
adjusting screw on gas valve and/or gas flow
restrictor.
B Check CO
2
adjustment.
no: 6.
6. B Change the gas valve.
1) See installation instructions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester GREENSTAR HE combi Series and is the answer not in the manual?

Worcester GREENSTAR HE combi Series Specifications

General IconGeneral
BrandWorcester
ModelGREENSTAR HE combi Series
CategoryBoiler
LanguageEnglish

Related product manuals