FLUE INSTALLATION
INSTALLATION & SERVICING INSTRUCTIONS FOR GREENSTAR HEATSLAVE II EXTERNAL 12/18-18/25-25/32
6 720 805 210-01
25
INSTALLATION
INSTALLATION NOTES:
4 Ensure all the seals are in good condition
and seated properly.
4 To ease assembly of flue components,
grease seals lightly with the solvent free
grease supplied.
4 A terminal guard must be fitted if the
terminal is 2m or less above a surface where
people have access.
All flue options:
1 4Lightly grease the flue cowl seal with the
solvent free grease supplied.
2 4Carefully remove the blanking plate from
the appropriate flue aperture (if necessary)
and refit the blanking plate in the unused
aperture.
3 4Carefully remove the insulation from the
flue aperture in the cabinet that the flue is
to pass through, and fit to the unused
aperture (if necessary).
4 4Refer to the flue manual supplied with the
flue kit for flue installation.
FLUE INSTALLATION