EasyManua.ls Logo

WTC 200 - Beep Sound; Automatic Shutdown

WTC 200
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
Press key, parameter values are displayed successively one by one,
where:
nonE
Backlight off.
10
Display brightness low limit value in [%].
100
Display brightness high limit value in [%].
Set the respective value, press key to confirm, next go to the home
screen.
17.3. 'Beep' Sound
Parameter allowing you to enable/disable sound signal informing the operator
about pressing panel key(s).
Procedure:
Enter <P7.Othr / 7.3.bEEP> submenu.
Press key, parameter values are displayed successively one by one:
no sound signal disabled, YES - sound signal enabled.
Press key to confirm, next go to the home screen.
17.4. Automatic Shutdown
Parameter allowing you to set time interval, in [min], after which the weighing
device shuts down automatically. If the indication is stable during the declared
time interval, the device is shut down automatically. Shutdown function
is inactive and the device cannot be turned off if any process is started or if you
operate the menu.
Procedure:
Enter <P7.Othr / 7.4.t1> submenu.
Press key, parameter values are displayed successively one by one:
nonE function disabled, 1, 2, 3, 5, 10.
Press key to confirm, next go to the home screen.