Procedure:
Enter <P3.Func> menu and select given working mode.
Enter <Int> function, window for entering time interval value is displayed.
Press key to confirm, next go to the home screen.
19.2.4. Lo Threshold
<Lo> parameter allows you to configure the function of automatic operation.
In order to save the next measurement, before carrying it out the mass
indication must get below the set net value of Lo threshold.
Procedure:
Enter <P3.Func> menu and select given working mode.
Enter <Lo> function, window for entering Lo threshold value is displayed.
Enter respective value and press key to confirm, then continue
weighing.
20. WORKING MODE – WEIGHING
<UUGG> is a standard working mode enabling you to carry out the weighing
operation along with record of the result to the database.
20.1. Local Settings
To go to local settings enter <3.1.UUGG> submenu.
Working mode accessibility
For detailed description read section 19.2.1.
For detailed description read section 19.2.2.
For detailed description read section 19.2.3.
For detailed description read section 19.2.4.
21. WORKING MODE – PARTS COUNTING
Parts Counting is a working mode enabling you to determine quantity of small
pieces of the same mass, which determination is done on the basis of mass
of sample piece (single part), and where the sample piece mass (single part
mass) is determined using the weighing device.