Ci7XX0 BENCHTOP SPECTROPHOTOMETER
10
Packaging Information
If you are reading this documentation, you have already followed the instructions detailed in the
Ci7XX0 installation sheet that was included in the shipping carton. Please keep the installation
sheet for reference. Keep your shipping carton in case you need to return your instrument to the
factory for service.
Your instrument packaging should contain all the items listed below. If any of these items are
missing or damaged, contact X-Rite or your Authorized Representative.
Software box containing the Ci7XX0 Driver and Documentation CD along with any other
optional software you may have ordered such as Color iControl and NetProfiler.
Ci7500 Series, Ci7600 Series, or Ci7800 Series Spectrophotometer
Certificate of performance
Installation instructions sheet
USB cable
AC power cord
Sample shelf with thumb screws
Transmission kit (optional on Ci7800 Series & Ci7600 Series)
The following accessories are stored in the instrument accessory drawer.
Round white calibration tile
Round green performance tile
Black trap for calibration
Ci7800 Series aperture plates: 25 mm, 17 mm, 10 mm, 6 mm, (3.5 mm optional)
Ci7600 Series aperture plates: 25 mm, 10 mm, 6 mm, (3.5 mm optional), (17 mm
optional)
Ci7500 Series aperture plates: 25 mm, 10 mm
White UV plaque
Instrument Setup
Please follow the instructions detailed in the Ci7XX0 Installation Instructions sheet found as the
first item in your shipping box when you opened it. A PDF file of the Installation Instructions also
can be found on the Ci7XX0 Driver and Documentation CD.
Powering the Instrument
The power on-off AC switch is located on the back of the instrument. Press the top of the rocker
switch to turn on the instrument and wait 50 seconds for the instrument to boot up. If the
instrument does not power up after approximately 50 seconds, check the power connections to
the unit and main power availability (breakers, fuses). If these connections are fine, check the
instrument’s fuse. Refer to “Fuse Replacement” in the Appendix.
A power “standby” button is located on the front panel of the instrument. This button is used to
power down the instrument into a low power state, or wake the instrument after it goes into a
power down state. A power on condition is designated by a solid green light indicator. Simply
press the power “standby” button to wake or power down the instrument into “standby” mode.
Discontinue use if AC cord is damaged.
Ensure AC cord ratings meet or exceed the instrument ratings (see Specifications section in
the Appendices).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the X-Rite Ci7860 Series and is the answer not in the manual?

X-Rite Ci7860 Series Specifications

General IconGeneral
BrandX-Rite
ModelCi7860 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals