Materials List
975-0822-01-01 3
Comprehensive
Protection
The Freedom Xâs built-in protection features
safeguard your batteries (from unnecessary
drain) such as the low battery voltage alarm
and shutdown and protect equipment such as
a configurable AC transfer speed.
n Selectable Low Battery Shutdown:
The low battery shutdown for the
inverter can be manually selected by the
user from 10.1 to 12.8îVZ.
n Voltage Shutdown Delay Timer:
Configurable from 1 to 300îs to reduce
an unnecessary shutdown of inverter
operation such as during cranking or
other brief but heavy discharge of
battery.
n Inverter Power Save: The Freedom X
can be programmed to automatically
turn off after 1 to 25 h of continued
operation of loads that are under 50îW.
It is designed, with LBCO (low battery
cut off), to prevent the battery from deep
discharge.
Configurable AC
Transfer Speed
The Freedom X allows two speed settings for
the AC transfer from Grid Mode to Battery
Mode and vice versa which avoids nuisance
resetting of appliances. The normal transfer
rate is for common appliances and the faster
transfer rate is designed for more sensitive
digital equipment like a desktop computer.
Overload Alarm
and Shutdown
During Battery Mode (also called Inverter
Mode), the Freedom X automatically alerts
you if the loads that are connected and
drawing power from the unit are close to
approaching the maximum operating limit. If
so, the Freedom X automatically shuts down
when the maximum operating limit is
exceeded. See Troubleshooting Reference on
page 67 for precautions.
Over temperature
Alarm and
Shutdown
During Battery Mode, the Freedom X
automatically alerts you if it is overheating
and approaching the over-temperature
shutdown limit. The Freedom X automatically
shuts down when the limit is exceeded. See
Troubleshooting Reference on page 67 for
precautions.