Basic Installation Procedures
26 Freedom X 2000 - 230V Owner's Guide
Step 5: Connecting AC Output to an
Existing AC Circuit
WARNING
ELECTRIC SHOCK AND FIRE HAZARDS
n Make sure wiring is disconnected from all electrical sources
before handling. All wiring must be done in accordance with
local and national electrical wiring codes.
n A manufacturer-tested and approved RCBO (Type B) must
be connected to the Freedom X AC output and RCBO
protection must be provided on every branch circuit feeding a
receptacle connected to the AC hard wired installation, if
local regulations require it.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
NOTICE
EQUIPMENT DAMAGE
n Do not connect any AC source (such as a generator or
utility power) to the AC output wiring of the Freedom X.
n The Freedom X will not operate if its output is connected
to AC voltage from a source, and potentially hazardous or
damaging conditions may occur. These conditions can
occur even if the inverter is off.
Failure to follow these instructions can result in equipment
damage.
Do not connect the Freedom X to an AC branch circuit that has
high-power consumption loads that exceed its output wattage
rating.
The Freedom X will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume more than
its rated output wattage.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom X 2000 and is the answer not in the manual?

Xantrex Freedom X 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
Efficiency90%
WaveformPure Sine Wave
ProtectionsOverload, Over Temperature, Short Circuit