Operating Limits
975-0822-01-01 57
Operating
Condition
Battery
Voltage
Comment
High
Voltage
Shutdown
17.0 volts
The display shows error code E02
alternating with the battery
voltage. The red status LED turns
on.
NOTE: Although the Freedom X
incorporates over-voltage
protection, it can still be damaged
if input voltage exceeds 18.0
volts.
Overload Conditions
There are two kinds of overload conditions–an overload warning
and an overload shutdown.
Overload
Warning
When the Freedom X’s AC load is approximately 100W
below the overload shutdown limit of rated watts, the
audible alarm beeps once and the LCD screen shows a
warning code E06.
Overload
Shutdown
When the Freedom X’s AC load increases to near
~2100W, the audible alarm beeps every 5s for 1min
and the LCD screen shows a error code E03. The Status
LED turns solid RED.