Operating Limits
975-0822-01-01 57
Operating
Condition
Battery
Voltage
Comment
High
Voltage
Shutdown
17.0 volts
The display shows error code E02
alternating with the battery
voltage. The red status LED turns
on.
NOTE: Although the Freedom X
incorporates over-voltage
protection, it can still be damaged
if input voltage exceeds 18.0
volts.
Overload Conditions
There are two kinds of overload conditions–an overload warning
and an overload shutdown.
Overload
Warning
When the Freedom X’s AC load is approximately 100W
below the overload shutdown limit of rated watts, the
audible alarm beeps once and the LCD screen shows a
warning code E06.
Overload
Shutdown
When the Freedom X’s AC load increases to near
~2100W, the audible alarm beeps every 5s for 1min
and the LCD screen shows a error code E03. The Status
LED turns solid RED.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom X 2000 and is the answer not in the manual?

Xantrex Freedom X 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
Efficiency90%
WaveformPure Sine Wave
ProtectionsOverload, Over Temperature, Short Circuit