Loading...
Operating Limits
975-0822-01-01 55
Operating Limits
These are the operating limits of the Freedom X:
n Power Output
n Input Voltage
n Overload Conditions
n High Surge Loads
n Over-temperature Conditions
Power Output
The Freedom X can deliver up to 2000watts
3
of continuous utility
grade sine wave AC power. The wattage rating applies to resistive
loads such as incandescent lights.
3
As the temperature on the Model Name 2 rises, it will gradually reduce its continuous power output from
2000 W at 4C ambient to 1500 W before the over-temperature shutdown occurs at 60°C ambient. See
Specifications on page 73.