Operating Limits
56 Freedom X 2000 - 230V Owner's Guide
Input Voltage
The allowable Freedom X input battery voltage ranges are shown
in the following table:
Operating
Condition
Battery
Voltage
Comment
Full
Operating
Range
LBCO
17.0 volts
Assuming the battery is full, the
inverter will operate until battery
voltage goes past below LBCO
d
and LBCO Shutdown delay timer
e
.
Low
Voltage
Recovery
<LBCO+0.2
volts
Inverter is able to recover and
continue to operate.
Table 10Input battery voltage range
d
To set LBCO, see Adjusting Settings in Configuration Mode on page 47.
e
To set LBCO Shutdown Delay Timer, see Input Voltage on page 56.
Operating
Condition
Battery
Voltage
Comment
Low
Voltage
Shutdown
<LBCO
The buzzer sounds a single one-
second low battery alarm beep
and the LCD screen shows error
code E01. After LBCO Shutdown
delay timer runs out, the unit shuts
down inverter output. The buzzer
stops beeping and the LCD screen
shows error code E01.
Instant Low
Voltage
Shutdown
<9.0 volts
After two seconds below the limit,
the unit shuts down inverter output
completely. LCD screen turns off
completely.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom X 2000 and is the answer not in the manual?

Xantrex Freedom X 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
Efficiency90%
WaveformPure Sine Wave
ProtectionsOverload, Over Temperature, Short Circuit

Related product manuals