EasyManuals Logo

Xantrex Freedom X 2000 User Manual

Xantrex Freedom X 2000
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
Adjusting Settings in Configuration Mode
50 Freedom X 2000 - 230V Owner's Guide
Setting Name
Setting
Number
Default
Value
Range of
Values
Description
Inverter Shutdown
Recovery
13 MAT
At0(auto-
restart)
MAT(manual
restart)
The inverter shuts down when there is an over temperature,
overload, and short circuit condition. Selecting ATO (auto-restart)
will allow the inverter to recover automatically from a shutdown up
to three times maximum. Selecting MAT (manual restart) allows the
user to restart the inverter by performing a manual reset, that is, by
acknowledging the restart via the display panel.
Audible Alarm
14 bON
bON (Audible)
BOF (Mute)
The alarm beeps once every 5s.
Reset all settings to their
default values
99 ndf
NDF (as is)
DEF (default)
ndF refers to current settings.
Choose def to restore all settings to their default values.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex Freedom X 2000 and is the answer not in the manual?

Xantrex Freedom X 2000 Specifications

General IconGeneral
Continuous Power2000W
Surge Power4000W
Input Voltage12V DC
Output Voltage120V AC
Output Frequency60 Hz
Efficiency90%
WaveformPure Sine Wave
ProtectionsOverload, Over Temperature, Short Circuit

Related product manuals