Adjusting Settings in Configuration Mode
50 Freedom X 2000 - 230V Owner's Guide
Setting Name
Setting
Number
Default
Value
Range of
Values
Description
Inverter Shutdown
Recovery
13 MAT
At0(auto-
restart)
MAT(manual
restart)
The inverter shuts down when there is an over temperature,
overload, and short circuit condition. Selecting ATO (auto-restart)
will allow the inverter to recover automatically from a shutdown up
to three times maximum. Selecting MAT (manual restart) allows the
user to restart the inverter by performing a manual reset, that is, by
acknowledging the restart via the display panel.
Audible Alarm
14 bON
bON (Audible)
BOF (Mute)
The alarm beeps once every 5s.
Reset all settings to their
default values
99 ndf
NDF (as is)
DEF (default)
ndF refers to current settings.
Choose def to restore all settings to their default values.