Adjusting Settings in Configuration Mode
50 Freedom X 2000 - 230V Owner's Guide
Setting Name
Setting
Number
Default
Value
Range of
Values
Description
Inverter Shutdown
Recovery
13 MAT
At0(auto-
restart)
MAT(manual
restart)
The inverter shuts down when there is an over temperature,
overload, and short circuit condition. Selecting ATO (auto-restart)
will allow the inverter to recover automatically from a shutdown up
to three times maximum. Selecting MAT (manual restart) allows the
user to restart the inverter by performing a manual reset, that is, by
acknowledging the restart via the display panel.
Audible Alarm
14 bON
bON (Audible)
BOF (Mute)
The alarm beeps once every 5s.
Reset all settings to their
default values
99 ndf
NDF (as is)
DEF (default)
ndF refers to current settings.
Choose def to restore all settings to their default values.