QMS 3825/3225/2025 User's G uide3-4
Routine M a intenan ce
Maintenance You Can Perform 2025
Message Appears at Maintenance Needed Instructions
Toner Out 10,000
pages
Replace:
■ Toner cartridge
Clean:
■ Quenching lamp
■ Separation pawls
■ Transfer corona
wire
page 3-5
page 3-11
page 3-12
page 3-15
Maintenance
Due
20,000
pages
Replace:
■ Main charger
■ Transfer/separation
charger
■ Ozone filter
page 3-20
page 3-20
page 3-22
Replace
Cleaner
30,000
pages
Replace:
■ Cleaning unit
page 3-18
Replace Drum 80,000
pages
Replace:
■ OPC Drum
■ Shield plate
page 3-23
page 3-20
WA RNING!
To preven t perso nal inju ry, always turn off the pr inter
before cleaning o r rep lacing prin ter p arts.
ACHTU NG!
U m Verletz unge n z u verm eiden, so llte der D rucker imm er
ausgesc haltet werde n, wenn Sie das Ge rät r einigen oder Dr uck erteile
austausc hen wo llen.